Signal and Information Processing

Error Calibration of Three-Axis Magnetic Heading Sensor

Expand

  • College of Electronics and Information, Northwestern Polytechnical University, Xi’an 710072, China

Received date: 2011-12-27

  Revised date: 2012-12-05

  Online published: 2012-12-05

Abstract

An improved least-square ellipsoid fitting method for calibrating of magnetic heading sensor is proposed to overcome instability of the traditional ellipsoid fitting algorithm due to singularity of the constraint matrix. The source of error and the mathematical model are discussed. A method of matrix block
decomposition is used to solve the singularity problem of constraint matrix in the traditional algorithm. The ellipsoid parameter is calculated using the least-square algorithm. The proposed method overcomes instability of the traditional algorithm and reduces computation complexity. Simulation and experiments show that the proposed method is effective in magnetic heading sensor calibration. The precision of calibrated heading is better than 0.42m.

Cite this article

FENG Wen-guang, LIU Shi-bin, LI Ju-ping, GUO Bo, YANG Shang-lin . Error Calibration of Three-Axis Magnetic Heading Sensor[J]. Journal of Applied Sciences, 2013 , 31(2) : 154 -158 . DOI: 10.3969/j.issn.0255-8297.2013.02.008

References

[1]       刘诗斌. 无人机磁航向测量的自动罗差补偿研究 [J]. 航空学报,2007, 28(2): 411- 414.
LIU Shibin. Study on automatic magnetic deviation compensation of magnetic heading measurement for UAV [J]. Acta Aeronautica et Astronautica Sinica, 2007, 28(2): 411- 414. (in Chinese)
[2]       Halil Ersin Soken, Chingiz Hajiyev. In flight magnetometer calibration via unscented Kalman filter [C]//2011 5th International Conference on Recent Advances in Space Technologies. Istanbul, Turkey, 2011: 885-890.
[3]       Jau-Hsiung Wang, Yang Gao. A new magnetic compass calibration algorithm using neural networks [J].  Measurement Science and Technology, 2006, 17(1): 153-160.
[4]       J.F. Vasconcelos, G. Elkaim, C. Silvestre, P. Oliveira, B. Cardeira. A geometric approach to strapdown magnetometer calibration in sensor frame [J]. IEEE Transactions on Aerospace and Electronic Systems, 2011, 47(2): 1293-1306.
[5]       Hui Yan, Changhan Xiao, Shengdao Liu, Zhaoyang Zhang. Horizontal error calibration method for triaxial fluxgate magnetometer [C]//Automation Congress. Hawaii, HI, 2008: 1-5.
[6]       黄学功,王炅. 地磁信号检测系统误差分析与补偿方法研究 [J]. 兵工学报,2011, 32(1): 33-36.
HUANG Xuegong, WANG Jiong. Error analysis and compensation methods for geomagnetic signal detection system [J]. Acta Armamentarii, 2011, 32(1): 33-36.(in Chinese)
[7]       Jiancheng Fang, Hongwei Sun, Juanjuan Cao, Xiao Zhang, Ye Tao. A novel calibration method of magnetic compass based on ellipsoid fitting [J]. IEEE Transactions on Instrumentation and Measurement, 2011, 60(6): 2053- 2061.
[8]       J. Vcelak, P. Ripka, A. Platil, J. Kub?k, P. Kaspar. Errors of AMR compass and methods of their compensation [J]. Sensors and Actuators A: Physical, 2006, 129(1-2): 53-57.
[9]       Nikos Grammalidis, Michael G.Strintzis. Head detection and tracking by 2-D and 3-D ellipsoid fitting [C]// Proceedings of the International Conference on Computer Graphics, Geneva, Switzerland, 2000: 221-226.
[10]    Vladimir Y. Skvortzov, Hyoung-Ki Lee, SeokWon Bang,  YongBeom Lee. Application of electronic compass for mobile robot in an indoor environment [C]//IEEE International Conference on Robotics and Automation. Roma, Italy, 2007: 2963- 2970.
[11]    Andrew Fitzgibbon, Maurizio Pilu, Robert B. Fisher. Direct least square fitting of ellipses [J]. IEEE Transactions on Pattern Analysis and Machine Intelligence, 1999, 21(5): 476-480.
[12]    Radim Hal?r, Jan Flusser. Numerically stable direct least squares fitting of ellipses [C]//The 6th International Conference in Central Europe on Computer Graphics and Visualization. Plzen, Czech, 1998:125-132.
[13]    Qingde Li, John G.Griffiths. Least squares ellipsoid speci?c fitting [C]//Proceedings of Geometric Modeling and Processing, Beijing, China, 2004: 335-340.
Outlines

/