Journal of Applied Sciences ›› 1988, Vol. 6 ›› Issue (1): 86-90.
• Articles • Previous Articles Next Articles
HUANG GENGCHEN1, ZHAO GUOZHBN2, WANG JINGSHENG1
Received:
Revised:
Online:
Published:
Abstract: A high resolution TeO2 acousto-optical deflector for radio spectral analysis was designed and manufactured according to the principle of off-axis abnormal Bragg diffraction. The theoretical resolution is 19kHz, while in practice, a resolution of 28.5kHz was achieved. The 1dB bandwidth is 22MHz. The deflection is a linear function of input power up to 100mW. An acousto-optical spectrograph with TeO2 deflector was constructed and an excellent result in the observation of dark cloud was obtained.
HUANG GENGCHEN, ZHAO GUOZHBN, WANG JINGSHENG. A HIGH RESOLUTION TeO2 ACOUSTO-OPTIC DEFLECTOR FOR RAD IO SPECTRAL ANALYSIS[J]. Journal of Applied Sciences, 1988, 6(1): 86-90.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: https://www.jas.shu.edu.cn/EN/
https://www.jas.shu.edu.cn/EN/Y1988/V6/I1/86