Journal of Applied Sciences ›› 1988, Vol. 6 ›› Issue (2): 185-188.
• Articles • Previous Articles
CAO GUANYI1, H. KANOH2
Received:
Revised:
Online:
Published:
Abstract: Single tube heat exchanger is a typical example of distributed parameter system. The mathematical modes obtained by using partial differential have some properties which do not hold for centralized parameter system, especially due to the existance of essential singular point. The effect of essential singular point on the system stability can be shown by root loci. The system dynamics can be improved by using phase-lead compensation.
CAO GUANYI, H. KANOH. STABILITY AND PHASE-LEAD COMPENSATION OF THE SINGLE TUBE HEAT EXCHANGER[J]. Journal of Applied Sciences, 1988, 6(2): 185-188.